The original Phase Perfect® digital phase converter supplies power to some of the most demanding industrial applications available under some of the most challenging conditions imaginable. Utility-quality three-phase power anywhere you need it.
Shop NowThe Phase Perfect® is also available in a compact, high-value, configuration where the customization options of the original are not required. These Enterprise models have the same modern digital phase conversion technology inside as the original.
Shop NowBased on the same phase conversion technology as its bigger brothers, but designed for home shop, light commercial, and single motor applications where the cost of the Enterprise and original Phase Perfect® are prohibitive.
Shop NowAn embedded microprocessor constantly ramps up or down based on the needs of the attached equipment. Full power is there when you need it without any wasted energy when you don’t. High efficiency under load and extremely low power utilization when not loaded add up to big cost savings compared to other phase conversion technologies.
The Phase Perfect® will also return power to your single-phase source when any three-phase load is in generating mode. Returning this power and making your utility meter run backwards is a much more efficient solution than wasting any excess power by heating a resistor.
Horsepower rating of largest or combined load that will be connected to the Phase Perfect®
The cost in cents per kilowatt/hour your utility charges you for electricity usage. You can estimate costs for your region by looking at the Average Price Chart on eia.gov.
Number of weeks per year and days per week you anticipate needing 3 Phase power available. For example: a business with typical operating hours might be 50 weeks per year and 5 days per week, while an elevator installation would require 52 weeks per year and 7 days per week.
The number of hours per day you anticipate not drawing a significant 3 Phase load. For example: a typical business might not draw a significant load right away in the morning, during breaks, or over the lunch hour, while an elevator might be idle 20 or more hours per day.
Phase Perfect® | Rotary Converter | |
---|---|---|
Starting Load Horsepower | 20 | 40 |
Standby Power Consumption | 80W | 2260W |
Idle Power Cost | $11.20 | $316.40 |
Phase Perfect®’s have been powering equipment outdoors in the harshest of conditions for over 20 years. The brownouts, outages, and surges in remote areas that see frequent blizzards, lightning storms, and other severe weather has helped our engineers harden the Phase Perfect® into a highly reliable product.
The electronics have been made extremely robust, including the addition of costly film type line filter capacitors and custom inductors. The chassis is available with a NEMA 3R outdoor rating, so you can mount it anywhere without worry. The onboard software has also been continually upgraded with advanced monitoring and protections to help keep the Phase Perfect® and your expensive equipment safe.
Phase converters have wildly different characteristics on their ability to start and run motor loads.
Read MoreCommon terms related to phase conversion technology used throughout this website and across the internet.
Read MoreMaintaining tight voltage balance significantly alters the performance and longevity of electric motors.
Read MoreOversizing, or splitting across multiple units, learn how to best accommodate available incoming power.
Read MoreStandard Features | simple | enterprise | performance |
---|---|---|---|
97%+ efficient solid-state phase conversionFull power, no waste | |||
Robust Load ProtectionsDigital monitoring to keep your equipment safe | |||
NEMA 3RAvailable on all models for outdoor mounting | |||
Utility-grade Balanced VoltageVoltage on all 3 phases maintained within 2% | * | ||
Multiple LoadsDesigned to start hard loads and run multiple loads simultaneously | ** | ||
Regenerative LoadsSuch as motors with electronic brakes like lathes | |||
460 V ModelsModels available for 230 V or 460 V installations | |||
50°C (122°F) RatedReady to be exterior mounted, even in harsh climates | *** | ||
Ducted CoolingProtects sensitive electronics even in dirty environments |
Optional Features | simple | enterprise | performance |
---|---|---|---|
Voltage Doubling230 V in, 460 V out, no transformer needed | |||
Panel Shop: Strikesorb Surge ProtectionMultiple-hit protection, the best available | |||
Panel Shop: Service DisconnectMake maintenance easy and meet code without an external disconnect |
In many situations 460V could result in significant cost savings, but too often those potential savings are eaten up by the need for a transformer. The voltage doubling Phase Perfect® turns single-phase 230V input into three-phase 460V output simply and reliably.
Read more about Voltage DoublingNot sure about phase converters? Are the differences between the Phase Perfect® and other options, and how those stack up to utility power giving you indecision? Read more about phase conversion or contact us
Read more about Phase Conversion