DXConfigured Panel

Phase Converting, General Purpose VFD

DX Series, powered by our DXL line, are crafted to be the go-to for all water well industry needs. Utilizing the latest advances in variable frequency drive technology, along with Phase Technologies refined 508A enclosure design, makes these VFDs the best choice for all motor control applications.

Choose from many custom options to tailor your DX to the specific needs of your system and set up your drive using the industry’s best and simplest to set up feature set.

Overview

Our DX model drive is perfect for all industrial and well water applications. With horsepower options all the way up to 500hp, this large utility drive is ideal for any operation large or small. Enjoy easy set up wizards, our intuitive user interface, and fully customizable specs guarantee your needs are met while enjoying industry leading power and efficiency.

Features

  • Rugged NEMA 3R enclosure designed for the outdoors
  • All steel construction
  • Protective insect guards
  • Pre-cut conduit openings
  • Large graphic display with black-lit screen & intuitive interface
  • Flexible I/O
  • Modbus 
  • Ethernet
  • Downloadable Parameters
  • 40°C (104°F) Rated

Easy Setup Wizards

  • Constant Pressure
  • Flow Control
  • Tank Level Control
  • Pump Down
  • Suction Pump
  • HVAC

Specifications

Operating Temperature Range:  -40 °C - 50 °C (-40 °F - 122 °F)
Input Phase:  single-phase, three-phase
Output Phase:  three-phase
Nominal Voltage Range:230 V - 460 V
Output Type:  V/f control
Short Circuit Withstand Rating:     65 kA RMS symmetrical amps
Analog Inputs:  (2) 4 - 20 mA, (1) 0 - 10 VDC
Digital Inputs:(4) programmable
Relay Outputs:  (2) programmable 30 VDC or 277 VAC, 10 A, 
 (2) programmable, 30 VDC, 2 A or 125 VAC, 0.5 A

Models

Input Voltage: 230
ModelHorsepowerInput VoltageOutput VoltageRelated Input Current Related Output Current Configure
DX005523023018 A18 A
DX0077.523023025 A25 A
DX0101023023031 A31 A
DX0151523023046 A46 A
DX0202023023061 A61 A
DX0252523023075 A75 A
DX0303023023091 A91 A
Input Voltage: 460
ModelHorsepowerInput VoltageOutput VoltageRelated Input Current Related Output Current Configure
DX40554604609 A9 A
DX4077.546046013 A13 A
DX4101046046018 A18 A
DX4151546046025 A25 A
DX4202046046031 A31 A
DX4252546046038 A38 A
DX4303046046046 A46 A
DX4404046046061 A61 A
DX4505046046077 A77 A
DX4606046046086 A91 A
DX47575460460101 A107 A
DX4100100460460134 A142 A
DX4125125460460163 A172 A
DX4150150460460188 A198 A
DX4200200460460237 A250 A
DX4250250460460288 A304 A
DX4300300460460346 A365 A
DX4350350460460394 A415 A
DX4400400460460454 A478 A
DX4500500460460560 A590 A